This browser does not support the video element.
Products Description
Advantage
1. Accurate measurement
2. Stable and reliable
3. Adjustable precision
The Flow Meter coverts the flow of petrol sent from the pump to the rotating movement with a crankshaft by means of piston's reciprocating movement for display on the counter. The flow meter can measure the flow of petrol very accurately.
Features
1. Specially pretty good piston which provide longer life time and precise accuracy.
2. No need to calibrate for working for 2,000,000 L/m.
3. Novel appearance, small body, excellent abrasion resistance, accurate measurement and long life & reliable service.
Details Images
Technical parameters of flow meter | ||||
1 | model Type | FM1(1)、FM1(2)、FM1(3)、FM1(4) | ||
2 | forms | Four-piston volumetric flowmeter (adjustable type) | ||
3 | Conditions of use of oil | A) Oil product name: gasoline, kerosene, diesel oil B) Common pressure: 0.3Mpa C) Viscosity: below 8 MPa · S D) Additives: 10-15% ethanol | ||
4 | Environmental conditions | A) Temperature: -25 ~ 40℃ B) Humidity: 5 ~ 95% | ||
5 | Use flow range | 5~90L | ||
6 | compressive strength | 4 MPa | ||
7 | structure pressure (can restore the function of pressure Force) | 2 MPa | ||
8 | emissions | 0.5L/flowmeter output shaft per revolution Adjusting hole adjustment: about 0.1% / 2 holes | ||
9 | device differential accuracy | Plus or minus 0.2% | ||
10 | adjustment range of device difference | -0.6% -- + 1.0% (Adjuster poor beyond this range will result in a regulator A damaged) | ||
11 | Pressure loss | 0.027 Mpa (40 l/min) | ||
12 | installation | Vertical installation (tilt less than 3°, the upper cover of the flowmeter shall be above | ||
13 | Vibration resistance | JISZ200 standard III | ||
14 | Consuming parts | Oil seal, after disassembly, sealing parts, friction parts | ||
15 | Daily inspection/precautions | A) Daily and regular spot inspection items: leakage, abnormal vibration, abnormal sound and poor device performance B) Precautions: 1. Do not mix with water and foreign matter 2. It is recommended to install it at the front end of the oil inlet of the flow meter Over 200 mesh strainers | ||
16 | Rotation direction of output shaft | Turn right (as seen from above the output shaft) |
content is empty!